Shut-Down and Longer Standstills
10 Shut-Down and Longer Standstills
10.1 Draining
DANGER
Electrical danger!
Before beginning work on the
unit or system, the following
measures must be carried out:
Deenergize.
Secure against being
switched on again.
Determine whether
deenergized.
Ground and short-circuit.
Cover or block off adjacent
energized parts.
WARNING
Danger due to gauge pressure
and vacuum!
Danger due to escaping fluid!
Before beginning work on the
unit or system:
Interrupt supply of operating
liquid.
Bleed lines and vacuum
pump/compressor
(depressurize).
Switch off the pump-motor unit.
The above safety precautions apply when
working on the unit or system.
Provide suitable catch containers below the
vacuum pump/compressor housing.
Open the screw plug (Fig. 7, Pg. 25,
Item 5).
Allow the liquid to drain out.
Close the screw plug again,
tightening torque T
t
= 2 ... 3 Nm
[1.48 ... 2.21 ft lbs].
10.2 Preparing for longer standstill
Before a longer standstill (from approx.
4 weeks) or when there is danger of frost,
proceed as follows:
Drain pump-motor unit as described in
Chapter 10.1, "Draining", Pg. 34.
Remove the pipe/hose from the intake or
discharge connection.
Pour ½ l [0.132 gal (US); 0.110 gal (UK)] of
preservative (rust protection oil, e.g.
Mobilarma 247 form Mobil Oil)
into the open intake or discharge
connection.
Close the intake and discharge connection,
as well as the operating-liquid port and
remount the disconnected pipes/hoses.
Guide a M6 or M8 bolt (depending on the
type) with a sufficient shank length through
the center opening into the fan guard and
screw into the shaft end on the external fan
side (see Fig. 14, Pg. 34).
Turn the shaft by hand using the bolt.
Remove the M6 or M8 bolt again.
You have two options for the standstill:
Either the pump-motor unit remains
connected in the system,
or the unit is removed for storage.
Fig. 14: Pour in preservative and turn shaft